![vspd 6.0 vspd 6.0](https://s2.studylib.net/store/data/018715207_1-047a6ff8106cccdeb8815de484f17c30-768x994.png)
If there is an error, a fault message is output to (d22) by means of a low signal and displayed visually by the “OK” LED (LED goes out) on the front plate. If no command value call-up is active, the digital call-up 0 is set.Įrror logics identify any cable break of the command value input for 4 to 20 mA as well as an inactive enable input.
![vspd 6.0 vspd 6.0](https://fastly.4sqi.net/img/general/200x200/439086963_UQopVhm4sdJqbhvn15RbzXrNYkUaEkCbKI-y0VSpdxE.jpg)
The control is activated by the H level at the enable input.
![vspd 6.0 vspd 6.0](https://s3.manualzz.com/store/data/036089834_1-0c7314ebb2f5c3573efd68ede1dfc834.png)
Vspd 6.0 generator#
The command value inputs can be varied by means of software in the signal level.Īpart from the internal ramp generation option, you can also influence the ramp for “up” and “down” from external signals with correct total and correct sign by means of the AI2 (b6/b8) and AI5 (b18/b20) analog inputs.įor the valves, the software configures a step function generator for the realization of the overlap jump if an overlapped control spool is selected. The digital command value is added to the analog command value with the correct sign, according to the set call-up. The analog input AI4 (b14/b16) is to be used for the command value presetting of ☑0 V, the analog input AI6 (b22/b24) for any command value presetting from 4 to 20 mA.Ĭommand values from 0 to +10 V (12.20 mA) control solenoid B.Ĭommand values from 0 to –10 V (4.12 mA) control solenoid A. The command value can be preset via digital command value call-ups and/or via analog inputs. More control inputs have the following functions:Įnable by the parameter set activated by the current call-up (H active)Īctivation of the outputs (acknowledge fault message with low→high edge) A call-up activates the command value for the valve spool position with the related ramp times. Data for configuration, command values and parameters are stored in a FLASH in a non-volatile form.įour binarily coded digital inputs are used to call up parameter sets (command values) from the memory in which you can store a maximum of 16 sets. The central unit of the amplifier is a microcontroller which controls the entire process.
Vspd 6.0 install#
I connected with Registry PE and removed HKEY_LOCAL_MACHINE\SYSTEM\ControlSet003\Enum\VSBC7 from registry and all keys and values with contains "eltima", "evsbc7.sys", "evserial7.sys" and also drivers created in my Windows 7 64 bit under from subdirectoried "contained evsbc7.inf_amd64_neutral" and "evserial7.inf_amd64_neutral" leaving backup in other drive.Īfter reboot system works fine, but unfortunetly now if I want to install program by setup vspd.exe in last step when driver may be installed I got following error messages.The valve amplifier is set-up as printed circuit board in Europe format 100 mm x 160 mm with daughter board, fitted on both sides. I reboot my system with Hiren Boot CD and Mini XP. Uninstaling product do not remove old entries about COM2 and COM3, which was invisible in any way under Device Manager after deleting. There was also still subkeys 00 in following location HKEY_LOCAL_MACHINE\SYSTEM\ControlSet003\Enum\VSBC7\DEVICES. So I tried many things, reinstalls and removing hidden items COM2 and COM3 in device manager. But after one run I cannot pair again COM2 with COM3 or any others. I used 7.2 demo version and all was fine.